If you would like to speak with one of our engineers, please Submit a Question or give us a call at the phone number here. In North America, To route your phone support request directly to a technical support engineer, call toll-free 1-888-382-1583 or 1-440-646-3434, select Option 3 (Technical Support), then select Option 5 (More Options). When prompted, enter the ThinManager Direct Dial Code 201.

Difference between revisions of "Ports"

From ThinManager Knowledge Base
Jump to: navigation, search
(Created page with "==TCP 2031== Thin Manager uses TCP 2031 to communicate with the thin clients as well as redundant or mirrored server. ==TCP 2032== Thin Manager Mobile uses TCP 2032 to commun...")
(No difference)

Revision as of 16:26, 12 September 2012

TCP 2031

Thin Manager uses TCP 2031 to communicate with the thin clients as well as redundant or mirrored server.

TCP 2032

Thin Manager Mobile uses TCP 2032 to communicate with the Thin Manager server.

TCP 3389

Thin Manager uses TCP 3389 for RDP sessions to the Thin Clients.

UDP 4900

Thin Manager uses UDP 4900 for the tftp transfer of thin client firmware from the server to the device.

TCP 5900

Thin Manager uses TCP 5900 for shadowing. If porting through a firewall, 5900 must be left open and not directed to the Thin Manager Server.