If you would like to speak with one of our engineers, please Submit a Question or give us a call at the phone number here. In North America, To route your phone support request directly to a technical support engineer, call toll-free 1-888-382-1583 or 1-440-646-3434, select Option 3 (Technical Support), then select Option 5 (More Options). When prompted, enter the ThinManager Direct Dial Code 201.

Ports

From ThinManager Knowledge Base
Revision as of 15:54, 9 July 2018 by Randycannady (talk | contribs) (UDP 4900)
Jump to: navigation, search


UDP 67

IP Address Assignment -- Used by the PXE Server (if using PXE boot) (ThinManager 5.0 and later).

UDP 69

TFTP -- Used to TFTP the firmware and/or modules to ThinManager Compatible thin clients. (ThinManager 5.0 and later). Standard TFTP implementations use a different source port on the ThinManager server after the initial TFTP request - see Wikipedia article for details.

TCP 1494

Citrix -- Used by the ICA protocol (if using ICA instead of RDP).

UDP 1758

MultiCast -- Used if MultiCasting is enabled in ThinManager.
This port is configurable by:

  • Double clicking on your server name to bring up the ThinManager Server Configuration Wizard
  • Click Next until you come to the Multicase Configuration page
  • Click Advanced to bring up the Advanced Options

TCP 2031

Configuration -- Used to pass the configuration from the ThinManager Server to the terminal (connection initiated from thinclient). Also used for automatic Synchronization between ThinManager servers.

TCP 3389

RDP -- Used by the RDP protocol (if using ThinManager v2.4.1 or later). Connection is initiated by thinclient to Remote Desktop server.

UDP 4900

TFTP -- Used to TFTP the firmware to ThinManager Ready thin clients. Standard TFTP implementations use a different source port on the ThinManager server after the initial TFTP request - see Wikipedia article for TFTP details.

TCP 5900

Shadowing -- Used to shadow terminals (connection initiated from ThinManager UI directly to thinclient). This can be changed on the Shadow Configuration page of the ThinManager Server Configuration Wizard.
This port is configurable by:

ICMP

Ping -- Used by WinTMC and Enforce Primary.